Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 16(14): 2120-2126, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38516903

RESUMO

Aluminium ions (Al3+) are widely present in industries and daily life and are closely related to human health and environmental protection. Therefore, it is crucial to detect their concentration. In this paper, a convenient and reliable small molecule fluorescent probe based on a dicyanoisophorone Schiff base and 2-pyridinecarbohydrazide has been developed. The probe is capable of selectively detecting Al3+ with the advantages of near-infrared emission (maximum emission wavelength of 625 nm), good selectivity, high sensitivity (detection limit of 2.18 × 10-7 M) and fast response time (15 s). It has good potential for rapid detection and visual tracking of Al3+ in aqueous solutions and plant bodies.


Assuntos
Alumínio , Corantes Fluorescentes , Humanos , Água , Cicloexanonas
2.
Biochem Biophys Res Commun ; 672: 185-192, 2023 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-37354612

RESUMO

Abnormal function of injured muscle with innervation loss is a challenge in sports medicine. The difficulty of rehabilitation is regenerating and reconstructing the skeletal muscle tissue and the neuromuscular junction (NMJ). Platelet-rich plasma (PRP) releases various growth factors that may provide an appropriate niche for tissue regeneration. However, the specific mechanism of the PRP's efficacy on muscle healing remains unknown. In this study, we injected PRP with different concentration gradients (800, 1200, 1600 × 109 pl/L) or saline into a rat gastrocnemius laceration model. The results of histopathology and neuromyography show that PRP improved myofibers regeneration, facilitated electrophysiological recovery, and reduced fibrosis in a concentration-dependent manner. Furthermore, we found that PRP promotes the activity of satellite cells by upregulating the expression of the myogenic regulatory factor (MyoD, myogenin). Meanwhile, PRP promotes the regeneration and maturation of acetylcholine receptor (AChR) clusters of the Neuromuscular junction (NMJ) on the regenerative myofibers. Finally, we found that the expression of the Agrin, LRP4, and MuSK was upregulated in the PRP-treated groups, which may contribute to AChR cluster regeneration and functional recovery. The conclusions proposed a hypothesis for PRP treatment's efficacy and mechanism in muscle injuries, indicating promising application prospects.


Assuntos
Lacerações , Doenças Musculares , Plasma Rico em Plaquetas , Ratos , Animais , Lacerações/metabolismo , Lacerações/patologia , Músculo Esquelético/patologia , Doenças Musculares/metabolismo , Plasma Rico em Plaquetas/metabolismo , Junção Neuromuscular/metabolismo , Receptores Colinérgicos/metabolismo
3.
Heart Surg Forum ; 26(6): E889-E895, 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38178330

RESUMO

BACKGROUND: Patients with coronary heart disease (CHD) often have other diseases due to organ dysfunction, among which chronic heart failure (CHF) is the most common. Percutaneous coronary intervention (PCI) is the mainstream method for the treatment of such diseases. Because most of the patients are the elderly and the functions of various organs are declining, it is necessary to implement scientific and efficient management methods. OBJECTIVE: To explore the application value of circulation quality control intervention (CQCI) mode in PCI of patients with CHD and CHF. Time: From June 2021 to June 2023. METHODS: The clinical data of 197 CHD patients with CHF were retrospectively analyzed, and 14 patients who did not meet the inclusion criteria were excluded. According to different perioperative management methods, the remaining cases were divided into the reference group (RG, receiving routine clinical management) and observation group (OG, receiving routine clinical management and CQCI). The cardiac function indexes and emotional state before and after management were compared between the two groups, and the quality of life in two groups was compared. RESULTS: In this study, 100 patients were included in the RG and 83 patients were included in the OG finally. Compared with the RG, the OG had lower levels of left ventricular end systolic diameter and left ventricular end-diastolic diameter after management (p < 0.05), while the OG had significantly higher left ventricular ejection fraction level (p < 0.001). The OG had overtly higher clinical satisfaction than the RG (p < 0.05). After management, the Hospital Anxiety and Depression Scale score in the OG were distinctly lower than those in the RG (p < 0.001). After management, the OG had significantly higher scores of physiological field, psychological field, social relationship and environmental field than the RG (p < 0.001). CONCLUSION: The application of CQCI mode in the perioperative period of PCI has certain benefits for improving the cardiac function of patients. At the same time, this program can also improve the quality of life of patients to a certain extent, which is helpful to accelerate postoperative rehabilitation.


Assuntos
Doença das Coronárias , Insuficiência Cardíaca , Intervenção Coronária Percutânea , Humanos , Idoso , Volume Sistólico , Função Ventricular Esquerda , Qualidade de Vida , Estudos Retrospectivos , Doença das Coronárias/complicações , Doença das Coronárias/cirurgia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia
4.
Front Bioeng Biotechnol ; 10: 928216, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36185453

RESUMO

Hydroxyapatite (HA) coatings have been widely used for improving the bone-implant interface (BII) bonding of the artificial joint prostheses. However, the incidence of prosthetic revisions due to aseptic loosening remains high. Porous materials, including three-dimensional (3D) printing, can reduce the elastic modulus and improve osseointegration at the BII. In our previous study, we identified a porous material with a sintered bionic trabecular structure with in vitro and in vivo bio-safety as well as in vivo mechanical safety. This study aimed to compare the difference in osseointegration ability of the different porous materials and HA-coated titanium alloy in the BII. We fabricated sintered bionic trabecular porous titanium acetabular cups, 3D-printed porous titanium acetabular cups, and HA-coated titanium alloy acetabular cups for producing a hip prosthesis suitable for beagle dogs. Subsequently, the imaging and histomorphological analysis of the three materials under mechanical loading in animals was performed (at months 1, 3, and 6). The results suggested that both sintered bionic porous titanium alloy and 3D-printed titanium alloy exhibited superior performances in promoting osseointegration at the BII than the HA-coated titanium alloy. In particular, the sintered bionic porous titanium alloy exhibited a favorable bone ingrowth performance at an early stage (month 1). A comparison of the two porous titanium alloys suggested that the sintered bionic porous titanium alloys exhibit superior bone in growth properties and osseointegration ability. Overall, our findings provide an experimental basis for the clinical application of sintered bionic trabecular porous titanium alloys.

5.
Am J Sports Med ; 50(13): 3660-3670, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36190157

RESUMO

BACKGROUND: The first-line clinical strategy for small cartilage/osteochondral defects is microfracture (MF). However, its repair efficacy needs improvement. HYPOTHESIS: Appropriate energy radial shockwave stimulation in MF holes would greatly improve repair efficacy in the porcine osteochondral defect model, and it may obtain comparable performance with common tissue engineering techniques. STUDY DESIGN: Controlled laboratory study. METHODS: Osteochondral defect models (8-mm diameter, 3-mm depth) were established in the weightbearing area of Bama pigs' medial femoral condyles. In total, 25 minipigs were randomly divided into 5 groups: control (Con; without treatment), MF, MF augmentation (MF+; treated with appropriate energy radial shockwave stimulation in MF holes after MF), tissue engineering (TE; treated with compounds of microcarrier and bone marrow mesenchymal stem cells), and sham (as the positive control). After 3 months of intervention, osteochondral specimens were harvested for macroscopic, radiological, biomechanical, and histological evaluations. The statistical data were analyzed using 1-way analysis of variance. RESULTS: Based on the macroscopic appearance, the smoothness and integration of the repaired tissue in the MF+ group were improved when compared with the Con and MF groups. The histological staining suggested more abundant cartilaginous matrix deposition in the MF+ group versus the Con and MF groups. The general scores of the macroscopic and histological appearances were comparable in the MF+ and the TE groups. The high signal areas of the osteochondral unit in the magnetic resonance images were significantly decreased in the MF+ group, with no difference with the TE group. The micro-computed tomography data demonstrated the safety of direct in situ radial shockwave performance. Biomechanical tests revealed that the repaired tissue's Young modulus was highest in the MF+ group and not statistically different from that in the TE group. CONCLUSION: Direct in situ radial shockwave stimulation with appropriate energy significantly improves the short-term repair efficacy of MF. More encouragingly, the MF+ group in our study obtained repair performance comparable with the TE therapy. CLINICAL RELEVANCE: This strategy is easy to perform and can readily be generalized with safety and higher cartilage repair efficacy. Moreover, it is expected to be accomplished under arthroscopy, indicating tremendous clinical transformative value.


Assuntos
Doenças das Cartilagens , Cartilagem Articular , Fraturas de Estresse , Fraturas Intra-Articulares , Animais , Doenças das Cartilagens/cirurgia , Cartilagem Articular/cirurgia , Fraturas de Estresse/cirurgia , Fraturas Intra-Articulares/patologia , Suínos , Porco Miniatura , Engenharia Tecidual , Microtomografia por Raio-X
6.
Orthop J Sports Med ; 9(4): 2325967121995803, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33954219

RESUMO

BACKGROUND: Medial patellofemoral ligament reconstruction (MPFLR) is widely used to treat patellofemoral instability. However, it is still unclear when a concomitant bony procedure is needed. PURPOSE: To evaluate the therapeutic efficacy of isolated MPFLR for recurrent patellar lateral dislocation and to identify the prognostic factors for clinical outcomes. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A total of 237 patients who had undergone unilateral isolated MPFLR between January 2011 and December 2016 were included. Patellar tracking (J sign) and radiologic information including patellar height, trochlear dysplasia, tibial tubercle-trochlear groove distance, and patellar tilt was collected preoperatively, and the Kujala and International Knee Documentation Committee (IKDC) functional scores were used to assess postoperative recovery. Failure was defined as redislocation or patient-reported and clinically confirmed patellar instability. The influence of radiologic features and the J sign on knee functional scores was explored via subgroup analysis. Potential prognostic factors were explored using univariate and multivariate regression analyses, and risk factors for a positive J sign were evaluated using Spearman coefficient correlation analysis. RESULTS: The mean ± SD follow-up period was 70.67 ± 18.05 months (range, 36-108 months). From preoperatively to final follow-up, all patients had statistically and clinically significant improvements in the Kujala score (from 51.43 ± 6.87 to 88.52 ± 4.83; P < .001) and IKDC score (from 49.78 ± 6.05 to 81.16 ± 4.20; P < .001). Subgroup analysis indicated no significant difference in functional score improvements based on radiologic features or the J sign. Overall, 20 knees (8.4%) experienced postoperative failure: 11 with redislocation and 9 with patellar instability. A preoperative positive J sign was shown to be an independent prognostic factor for postoperative failure via logistic regression analyses: univariate (odds ratio, 3.340; 95% CI, 1.316-8.480; P = .011) and multivariate (odds ratio, 3.038; 95% CI, 1.179-7.827; P = .021). In addition, the J sign was closely associated with patellar height (r S, 0.159; P = .014) and trochlear dysplasia (r S, 0.235; P < .001). CONCLUSION: Isolated MPFLR appears to be an effective strategy for recurrent patellar lateral dislocation, with significant functional improvement and a low failure rate. A preoperative positive J sign was identified as a potential prognostic risk factor for postoperative failure.

7.
RSC Adv ; 11(9): 5128-5138, 2021 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35424426

RESUMO

A new highly controlled powder sintering technique was used for the fabrication of a porous Ti6Al4V scaffold. The platelet-rich plasma (PRP) was prepared using whole blood. The PRP was used as a cell carrier to inject bone marrow mesenchymal stem cells (MSC) into the pores of the Ti6Al4V scaffold in the presence of calcium chloride and thrombin, and then the composite construct of porous Ti6Al4V loaded with PRP gel and MSC was obtained. The bare Ti6Al4V scaffold and the Ti6Al4V scaffold loaded with MSC were used as controls. The characteristics and mechanical properties of the scaffold, and the biological properties of the constructs were evaluated by a series of in vitro and in vivo experiments. The results show that the sintered porous Ti6Al4V has good biocompatibility, and high porosity and large pore size, which can provide sufficient space and sufficient mechanical support for the growth of cells and bones without an obvious stress shielding effect. However, Ti6Al4V/MSC/PRP showed a significantly higher cell proliferation rate, faster bone growth speed, more bone ingrowth, and higher interfacial strength. Therefore, the porous Ti6Al4V scaffolds incorporated with MSC and PRP may be more effective at enhancing bone regeneration, and is expected to be used for bone defect repair.

8.
Phys Med Biol ; 65(23)2020 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-33086214

RESUMO

The performance of dual-ended readout depth-encoding positron emission tomography (PET) detectors based on bismuth germanate (BGO) coupled to silicon photomultipliers (SiPM) arrays was measured for the first time and compared to lutetium-yttrium oxyorthosilicate (LYSO)-based detectors using the same readout. The BGO and LYSO crystal arrays all had a crystal pitch of 2.2 mm and were coupled to 8 × 8 SiPM arrays with a matching pitch of 2.2 mm, using a one-to-one coupling configuration. Three types of crystals with Toray reflector were used: polished LYSO, polished BGO, and unpolished BGO, and for two different crystal thicknesses of 20 mm and 30 mm. All the crystal elements in the BGO arrays were clearly resolved in the flood histogram. Better flood histograms were obtained using the LYSO arrays for a selected crystal thickness, and better flood histograms were obtained using the 20 mm thick crystal arrays for a selected crystal type. The average crystal level energy resolution and timing resolution for 20 mm polished LYSO, polished BGO and unpolished BGO crystals at their optimal SiPM bias voltage were 18.6 ± 1.3% and 1.19 ± 0.20 ns, 17.8 ± 0.8% and 4.43 ± 0.47 ns, and 18.0 ± 1.0% and 4.68 ± 1.0 ns, respectively. Depth-of-interaction (DOI) resolution of the 20 mm polished LYSO array was 2.31 ± 0.17 mm and for the 20 mm unpolished BGO array was 3.53 ± 0.25 mm. However, polished BGO arrays with Toray reflector did not provide DOI information. Our key conclusion is that dual-ended readout depth-encoding 20 mm thick unpolished BGO detectors are good candidates for low-activity PET systems with small field-of-view and low timing performance requirements, such as preclinical or compact organ-dedicated PET systems, with the advantage over LYSO of having no background radiation and significantly lower cost.


Assuntos
Lutécio , Ítrio , Radiação de Fundo , Bismuto , Germânio , Lutécio/química , Tomografia por Emissão de Pósitrons/métodos
9.
Phys Med Biol ; 65(16): 165011, 2020 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-32580180

RESUMO

A dual-ended readout PET detector based on two Hamamatsu 16 × 16 arrays of 1 × 1 mm2 SiPMs coupled to both ends of a 25 × 25 array of 0.69 × 0.69 × 20 mm3 polished LYSOs was evaluated in terms of flood histogram, energy resolution, timing resolution, and DOI resolution. The SiPM arrays have a pitch size of 1.2 mm. Each SiPM pixel has an active area of 1 × 1 mm2, and was fabricated using 15 µm microcells. The LYSO array has a pitch size of 0.75 mm, and the crystals are separated using Toray reflector with a thickness of 50 µm. The flood histogram and energy resolution were measured at different overvoltages (ranging from 1.5 to 7.0 V, in 0.5 V steps) and at four different temperatures (-7, 0, 10 and 20 °C). The timing resolution and DOI resolution were obtained at the optimal overvoltage for the flood histogram and at each different temperature. Overall, the results show better performance was obtained at lower temperatures, and that the optimal overvoltage decreased at higher temperatures. The optimal overvoltage was 5.0 V (corresponding to a bias voltage of 68.5 V) in order to achieve the highest quality flood histogram at 0 °C. Under these conditions, the flood histogram quality, energy resolution, timing resolution, and DOI resolution were 3.26 ± 0.65, 18.4 ± 4.5%, 1.70 ± 0.12 ns and 2.22 ± 0.19 mm, respectively. The flood histograms and energy resolution were also obtained at different activities. The results show that better flood histogram and energy resolution were obtained at lower activity, however all the crystals can be resolved at an event rate of over 210 k cps, indicating the DOI detector module can be used both for high resolution human brain PET and small animal PET applications.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Silício/química , Animais , Temperatura Baixa , Humanos
10.
Phys Med Biol ; 64(23): 235004, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31618708

RESUMO

Brain PET scanners that simultaneously provide high-resolution across the field-of-view and high-sensitivity can be constructed using detectors based on SiPM arrays coupled to both ends of scintillator arrays with finely segmented and long detector elements. To reduce the dead space between detector modules and hence improve the sensitivity of PET scanners, crystal arrays with curved surfaces are proposed. In this paper, the performance of a proof-of-concept detector module with nine detector submodules based on SiPMs coupled to both ends of a curved LYSO array with a pitch size of 1.0 × 1.0 mm2 at the front-end and a length of 30 mm was evaluated. A simple signal multiplexing method using the shared-photodetector readout method was evaluated to identify the crystals. The results showed that all the LYSO elements in the detector module of interest could be clearly resolved. The energy resolution, depth-of-interaction resolution, and timing resolution were 14.6% ± 3.6%, 2.77 ± 0.39 mm, and 1.15 ± 0.07 ns, respectively, obtained at a bias voltage of 28.0 V and a temperature of 16.8 °C ± 0.2 °C.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/instrumentação , Eletrônica , Desenho de Equipamento , Humanos , Distribuição Normal , Valores de Referência , Reprodutibilidade dos Testes , Contagem de Cintilação/instrumentação , Contagem de Cintilação/métodos , Processamento de Sinais Assistido por Computador , Temperatura
11.
Phys Med Biol ; 64(15): 15NT03, 2019 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-31018180

RESUMO

Silicon photomultipliers (SiPMs) are widely used in positron emission tomography (PET), however, SiPMs from different vendors vary in their performance characteristics. In addition, the specifications provided by the manufacturers are measured under different operating conditions and using different test setups, making it difficult to choose the optimal device for a specific application using the published specifications. In this work, we evaluated four state-of-the-art 8 × 8 arrays of ~3 × 3 mm2 SiPMs from SensL, KETEK, and Hamamatsu for high-resolution dual-ended readout detectors using the same experimental setup and procedures. The results showed that all four SiPM arrays are excellent candidates for high-resolution PET applications, although some interesting differences in performance were noted.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Limite de Detecção , Fótons , Tomografia por Emissão de Pósitrons/normas , Doses de Radiação , Silício/química , Silício/efeitos da radiação
12.
Bioresour Technol ; 273: 77-85, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30415072

RESUMO

In this study, the effects of a macroporous catalyst (CaO), mesoporous catalyst (MCM-41), and microporous catalysts (ZSM-5 and SAPO-34) on the production of light olefins and aromatics from cellulose catalytic fast pyrolysis were investigated in a dual-catalyst fixed bed reactor. Further the fractional catalytic pyrolysis of MCM-41 or CaO with ZSM-5 or SAPO-34 was explored. The results showed that ZSM-5 was the most efficient catalyst for the formation of light olefins and aromatics followed by MCM-41, CaO and SAPO-34, and no aromatics were found with SAPO-34 only. Moreover, 15% CaO combined 85% ZSM-5 produced the highest yield of light olefins (5.59%) and aromatic (13.42%). The addition of CaO and MCM-41 promoted the selectivity of C2H4 and decreased the production of naphthalene.


Assuntos
Alcenos/química , Celulose/química , Biomassa , Catálise , Pirólise , Dióxido de Silício/química , Zeolitas/química
13.
Phys Med Biol ; 63(24): 245019, 2018 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-30523925

RESUMO

The performance of a depth-of-interaction (DOI) encoding PET detector module with dual-ended readout of LYSO scintillator arrays using large-area SiPM arrays was evaluated. Each SiPM array, with a surface area of 50.2 × 50.2 mm2, consists of 12 × 12 C-series SiPMs from SensL (SensL, Inc). The LYSO array, with a total size of 46 × 46 mm2 and a pitch size of 1.0 mm, consists of a 46 × 46 array of 0.945 × 0.945 × 20 mm3 polished LYSO crystals, separated by Toray reflector. Custom front-end electronics were designed to reduce the 288 SiPM signals of one detector module to nine signals, eight for position information and 1 for timing information. Schottky diodes were used to block noise from SiPMs that did not detect a significant number of scintillation photons following a gamma interaction. Measurements of noise, signal, signal-to-noise ratio, energy resolution and flood histogram quality were obtained at different bias voltages (26.0 to 31.0 V in 0.5 V intervals) and at two temperatures (5 °C and 20 °C). Clear acrylic plates, 2.0 mm thick, were used as light guides to spread the scintillation photons. Timing resolution, depth of interaction resolution, and the effect of event rate on detector performance were measured at the bias voltage determined to be optimal for the flood histograms. Performance obtained with and without the noise-blocking Shottky diodes was also compared. The results showed that all crystals in the LYSO array can be clearly resolved, and performance improved when using diodes to block noise, and at the lower temperature. The average energy resolution, flood histogram quality, timing resolution and DOI resolution were 23.8% ± 2.0%, 1.54 ± 0.17, 1.78 ± 0.09 ns and 2.81 ± 0.13 mm respectively, obtained at a bias voltage of 30.0 V and a temperature of 5 °C using the diode readout method. The event rate experiments showed that the flood histogram and energy resolution of the detector were not significantly degraded for an event rate of up to 150 000 counts s-1.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Razão Sinal-Ruído , Silício/química , Animais , Encéfalo/diagnóstico por imagem , Mama/diagnóstico por imagem , Temperatura Baixa , Eletrônica , Desenho de Equipamento , Raios gama , Humanos , Processamento de Imagem Assistida por Computador , Fótons
14.
Phys Med Biol ; 63(20): 205002, 2018 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-30204125

RESUMO

Sensitivity is an important performance characteristic of positron emission tomography (PET) systems. Improved sensitivity can be used to reduce injected dose, reduce scan time, or improve the signal-to-noise ratio and temporal resolution for dynamic studies. One way to improve the sensitivity of PET scanners is to reduce the gaps between detector modules. In this paper, a new signal processing method, named the shared-photodetector readout method, is proposed and evaluated. In this method, the signals generated in nearest neighbor photodetectors adjacent to the detector module of interest, were used to help identify the interaction location in the detector module of interest. Using this method, scintillator array-based detector modules with almost 100% packing fraction can be built, and the edge crystals can be clearly resolved, even when the crystals are small compared to the photodetector size. To evaluate this signal processing concept in one dimension, a detector block with four dual-ended readout detector modules, was designed. The detector block consisted of eight 4 × 4 arrays of SensL MicroFJ-30035 SiPMs coupled to both ends of a 14 × 56 array of 0.9 × 0.9 × 20 mm3 LYSO elements with a pitch size of 0.96 mm and a length of 20 mm. Performance in terms of energy resolution, flood histogram, timing resolution and depth-of-interaction resolution obtained using the shared-photodetector readout method were compared to those obtained using a conventional readout method. The results show that better over-all performance was achieved using the shared-photodetector readout method, especially at the edges and corners of the array.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Razão Sinal-Ruído , Tomografia por Emissão de Pósitrons/instrumentação
15.
Artigo em Inglês | MEDLINE | ID: mdl-30221010

RESUMO

This work presents a method to improve the separation of edge crystals in PET block detectors. As an alternative to square-shaped crystal arrays, we used an array of triangular-shaped crystals. This increases the distance between the crystal centres at the detector edges potentially improving the separation of edge crystals. To test this design, we have compared the flood histograms of two 4×4 scintillator arrays in both square and triangular configurations. The quality of the flood histogram was quantified using the fraction of events positioned in the correct crystal based on a 2D Gaussian fit of the segmented flood histograms. In the first study, the two crystal arrays were coupled with the SiPM directly using optical grease, and the flood histogram quality for the edge and corner crystals in the triangular-shaped array were much better than that for those crystals in the square-shaped array. The average light collection efficiency for the triangular-shaped array was 5.9% higher than that for the square-shaped array. The average energy resolution for the triangular and square shape array were 11.6% and 13.2% respectively. In the second study, two light guides with thickness 1 mm and 2 mm were used between the crystal arrays and the SiPM. The thicker lightguide degraded the light collection efficiency and energy resolution due to the light loss introduced by the light guide. However, in the 2-mm thick lightguide case, the flood histogram quality for the edge and corner crystals in the square-shaped array were improved due to better separation of those crystals in the flood histogram. Comparing the performance of the two crystal arrays with three different light guides, the triangular-shaped crystal array with no lightguide gave the best performance.

16.
Phys Med Biol ; 63(3): 035035, 2018 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-29324437

RESUMO

The goal of this study was to exploit the excellent spatial resolution characteristics of a position-sensitive silicon photomultiplier (SiPM) and develop a high-resolution depth-of-interaction (DOI) encoding positron emission tomography (PET) detector module. The detector consists of a 30 × 30 array of 0.445 × 0.445 × 20 mm3 polished LYSO crystals coupled to two 15.5 × 15.5 mm2 linearly-graded SiPM (LG-SiPM) arrays at both ends. The flood histograms show that all the crystals in the LYSO array can be resolved. The energy resolution, the coincidence timing resolution and the DOI resolution were 21.8 ± 5.8%, 1.23 ± 0.10 ns and 3.8 ± 1.2 mm, respectively, at a temperature of -10 °C and a bias voltage of 35.0 V. The performance did not degrade significantly for event rates of up to 130 000 counts s-1. This detector represents an attractive option for small-bore PET scanner designs that simultaneously emphasize high spatial resolution and high detection efficiency, important, for example, in preclinical imaging of the rodent brain with neuroreceptor ligands.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Contagem de Cintilação/instrumentação , Silício/química , Animais , Roedores
17.
IEEE Trans Nucl Sci ; 63(1): 8-16, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27182077

RESUMO

The performance of an 8 × 8 array of 6.0 × 6.0 mm2 (active area) SiPMs was evaluated for PET applications using crystal arrays with different pitch sizes (3.4 mm, 1.5 mm, 1.35 mm and 1.2 mm) and custom designed five-channel front-end readout electronics (four channels for position information and one channel for timing information). The total area of this SiPM array is 57.4 × 57.4 mm2, and the pitch size is 7.2 mm. It was fabricated using enhanced blue sensitivity SiPMs (MicroFB-60035-SMT) with peak spectral sensitivity at 420 nm. The performance of the SiPM array was characterized by measuring flood histogram decoding quality, energy resolution, timing resolution and saturation at several bias voltages (from 25.0 V to 30.0 V in 0.5 V intervals) and two different temperatures (5 °C and 20 °C). Results show that the best flood histogram was obtained at a bias voltage of 28.0 V and 5 °C and an array of polished LSO crystals with a pitch as small as 1.2 mm can be resolved. No saturation was observed up to a bias voltage of 29.5 V during the experiments, due to adequate light sharing between SiPMs. Energy resolution and timing resolution at 5 °C ranged from 12.7 ± 0.8% to 14.6 ± 1.4 % and 1.58 ± 0.13 ns to 2.50 ± 0.44 ns, for crystal array pitch sizes of 3.4 mm and 1.2 mm respectively. Superior flood histogram quality, energy resolution and timing resolution were obtained with larger crystal array pitch sizes and at lower temperature. Based on our findings, we conclude that this large-area SiPM array can serve as a suitable photodetector for high-resolution small-animal PET or dedicated human brain PET scanners.

18.
J Nucl Med ; 57(7): 1130-5, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27013696

RESUMO

UNLABELLED: We developed a prototype small-animal PET scanner based on depth-encoding detectors using dual-ended readout of small scintillator elements to produce high and uniform spatial resolution suitable for imaging the mouse brain. METHODS: The scanner consists of 16 tapered dual-ended-readout detectors arranged in a 61-mm-diameter ring. The axial field of view (FOV) is 7 mm, and the transaxial FOV is 30 mm. The scintillator arrays consist of 14 × 14 lutetium oxyorthosilicate elements, with a crystal size of 0.43 × 0.43 mm at the front end and 0.80 × 0.43 mm at the back end, and the crystal elements are 13 mm long. The arrays are read out by 8 × 8 mm and 13 × 8 mm position-sensitive avalanche photodiodes (PSAPDs) placed at opposite ends of the array. Standard nuclear-instrumentation-module electronics and a custom-designed multiplexer are used for signal processing. RESULTS: The detector performance was measured, and all but the crystals at the very edge could be clearly resolved. The average intrinsic spatial resolution in the axial direction was 0.61 mm. A depth-of-interaction resolution of 1.7 mm was achieved. The sensitivity of the scanner at the center of the FOV was 1.02% for a lower energy threshold of 150 keV and 0.68% for a lower energy threshold of 250 keV. The spatial resolution within a FOV that can accommodate the entire mouse brain was approximately 0.6 mm using a 3-dimensional maximum-likelihood expectation maximization reconstruction. Images of a hot-rod microphantom showed that rods with a diameter of as low as 0.5 mm could be resolved. The first in vivo studies were performed using (18)F-fluoride and confirmed that a 0.6-mm resolution can be achieved in the mouse head in vivo. Brain imaging studies with (18)F-FDG were also performed. CONCLUSION: We developed a prototype PET scanner that can achieve a spatial resolution approaching the physical limits of a small-bore PET scanner set by positron range and detector interaction. We plan to add more detector rings to extend the axial FOV of the scanner and increase sensitivity.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/instrumentação , Animais , Eletrônica , Desenho de Equipamento , Fluordesoxiglucose F18 , Processamento de Imagem Assistida por Computador , Lutécio , Camundongos , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Silicatos
19.
Zhongguo Yi Liao Qi Xie Za Zhi ; 38(1): 26-9, 2014 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-24839843

RESUMO

The basic mechanical properties of a Radial Shock Wave Therapy Equipment (RSWTE) were experimentally studied in this paper. The output energy of the RSWTE working on the operation frequency of 10 Hz was measured by dynamic pressure transducer under the conditions of different operation pressure. The results showed that both operation pressure and operation frequency have effects on the output energy of the equipment. The output energy increases with the increase of operation pressure, and the magnitude of increased energy decreases with higher operation of frequency. With the increase of operation frequency, the output energy rises up in condition of lower operation pressure and drops off in condition of higher operation pressure. The accurate medical treatment should be selected with the optimized energy and condition according to the treatment requirement to different illness in clinical medical applications.


Assuntos
Ondas de Choque de Alta Energia , Modalidades de Fisioterapia/instrumentação , Desenho de Equipamento , Pressão
20.
J Orthop Res ; 32(6): 744-51, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24536004

RESUMO

A central clinical challenge regarding the surgical treatment of bone and joint conditions is the eventual loosening of an orthopedic implant as a result of insufficient bone ingrowth at the bone-implant interface. We investigated the in vivo effectiveness of a coating containing recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded microspheres applied to acid-etched Ti6Al4V cylinders for implantation. Three groups of rabbits (24 per group) were used for implantation: (1) acid-etched Ti6Al4V implants coated with a mixture of rhBMP-2-loaded microspheres (125 ng rhBMP-2/mg microspheres) and α-butyl cyanoacrylate; (2) acid-etched, uncoated implants; and (3) bare, smooth uncoated implants. After implantation, 12 rabbits from each group were used for bone ingrowth determination at 4, 5, 6, 7, 8, and 12 weeks (2 rabbits per time point), while the remainder were used for histological analysis and push-out testing at 12 weeks. Scanning electron microscopy showed significant improvement in bone growth of the rhBMP-2 microspheres/α-butyl cyanoacrylate group compared with the other groups (p<0.01). Histological analysis and push-out testing also demonstrated enhanced bone growth of the rhBMP-2 group over that in the other two groups (p<0.01). The rhBMP-2 group showed the most significant bone growth, suggesting that coating acid-etched implants with a mixture of rhBMP-2-loaded microspheres and α-butyl cyanoacrylate may be an effective method to improve the osseointegration of orthopedic implants.


Assuntos
Desenvolvimento Ósseo/efeitos dos fármacos , Proteína Morfogenética Óssea 2/administração & dosagem , Fator de Crescimento Transformador beta/administração & dosagem , Ligas , Animais , Materiais Revestidos Biocompatíveis , Embucrilato , Humanos , Implantes Experimentais , Microesferas , Osseointegração , Coelhos , Proteínas Recombinantes/administração & dosagem , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...